• Portable Air Cooled and Water Cooled Chiller
  • Portable Air Cooled and Water Cooled Chiller
  • Portable Air Cooled and Water Cooled Chiller
  • Portable Air Cooled and Water Cooled Chiller
  • Portable Air Cooled and Water Cooled Chiller
  • Portable Air Cooled and Water Cooled Chiller

Portable Air Cooled and Water Cooled Chiller

Type: Air-Cooled
Cooling Method: Air-cooled
Unit Structure: Integral
Selected Voltage: 380V/50HZ
Compressor Number: 1, 2, 3, or 4 Sets
Noise Level: Ultra Quiet
Customization:
Gold Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
HTC
Application Fields
Plastic
Application Machine
Machining Center
Certification
ISO, CE
Condition
New
Evaporator Type
Tube-in-Shell
Refrigerant
R22/ R407/R407/A134 Optional
Compressor
Hermetic Scroll Closed Type
Condenser Type
Inner Threaded Copper Finned
Pump Type
Stainless Steel Centrifugal Pumps
Tolerance
0.5degree C
Cooling Capacity
9.5-950kw
Transport Package
Wooden Case
Specification
CE, SGS, ISO9001
Trademark
Hadrdega
Origin
Tianjin, China
HS Code
841869909
Production Capacity
300sets/Months

Product Description


Portable Air Cooled and Water Cooled Chiller

CHILLER
WATER-COOLED and AIR-COOLED


APPLICATION
Plastic, electronics manufacturing, electroplating, food, medical, chemical, printing, laser, machining and other industries.

FEATURES                                                                                                                                                                                               
• Japan Panasonic compressor, high efficiency, low noise, quiet operation
• Emerson imported refrigeration accessories with stable performance
• High efficiency evaporator and condenser, save energy by more than 30%
• The electrical parts are all genuine Siemens from Germany, ensuring stable operation of the machine.
• All pipeline insulation design to prevent local convection of the body pipeline
• Built-in automatic water supply device with box evaporator

SAFETY SYSTEM                                                     
• Compressor overload protection
• Pump overload protection
• Poor heat dissipation protection
• Insufficient refrigerant protection
• Refrigerant shortage protective
• High voltage protection
• Low voltage protection
• Power reverse phase loss phase protection
• Fault alarm buzzer


Portable Air Cooled and Water Cooled ChillerPortable Air Cooled and Water Cooled Chiller
TECHNICAL PARAMETER

WATER-COOLED CHILLER
Model HTC5W HTC8W HTC10W HTC12W HTC15W HTC20W HTC25W HTC30W HTC40W HTC50W
Cooling Capacity kW/h 50Hz
60Hz
15
18
24
28
30
36
34
41
49
58
61
72
68
82
97
116
122
146
137
164
Kcal/h 50Hz
60Hz
12900
15394
20296
24338
25800
30960
29412
35260
41710
50052
52460
62092
58738
70606
83420
100104
104920
125904
117476
140972
Input Power kW 5 8 10 11 15 20 22 31 39 49
Voltage 3PH-380V-50Hz (Or 200V/220V/415V 50Hz/60Hz)
Refrigerant Name R22 (Or R134a/R407c)
Control Method Externally balanced thermal expansion valve
Compressor Type Hermetic gyral type
(KW) Power 3.73 5.97 7.46 8.95 11.19 14.92 18.64 22.38 29.84 37.28
Evaporator Type Water tank with coil
(m³/h)
Chilled Water
2.6
3.2
4.1
4.9
5.2
6.2
5.9
7.1
8.4
10.0
10.0
12.1
11.8
14.1
16.7
20.0
20.6
24.7
23.5
28.2
(L)
Water Tank
50 120 120 160 200 250 250 265 330 350
(Inch)
Water Pipe
1 1- 1/ 2 1- 1/ 2 2 2 2-1/2 2- 1/ 2 2- 1/ 2 3 3
Condenser Type Copper tube high efficiency shell and tube type
(m³/h)
Cooling Water
3.5
4.2
5.2
6.1
6.8
7.4
7.9
9.3
10.7
11.7
13.9
16.3
15.8
18.6
20.5
22.7
27.8
33.4
31.6
37.9
(Inch) Water Pipe 1-1/2 1-1/2 1-1/2 1-1/2 2 2 2-1/2 3 3 3
Pump (kW) Power 0.37 0.75 0.75 0.75 1.5 2.25 2.25 2.25 3.75 4.5
Head, H (m) 20 22 22 22 24 30 30 30 40 52
Dimensions L (MM) 1070 1300 1300 1300 1535 1835 1835 1880 2100 2200
W (MM) 600 710 710 710 800 800 800 910 1100 1150
H (MM) 975 1390 1390 1390 1514 1514 1514 1600 1960 2100
Weight Kg 210 300 370 430 700 750 800 950 1200 1300
Unit Conversion 1KW=860KCAL/HR 1RT=3024KCAL/HR 1BTU/HR=0.252KCAL/HR
Note:
Working condition: Chilled water temperature range: 3°C to 35°C, temperature difference between inlet and outlet chilled water: 3°C to 8°C, cooling water temperature range: 18°C to 37°C,  temperature difference between inlet and outlet cooling water: 3.5°C to 10°C

Nominal cooling capacity calculated according to: inlet/outlet chilled fluid temperature: 12°C/7°C, inlet/outlet cooling water temperature: 30°C/35°C
• The above parameters are test results based on voltage 380V 50HZ 3-phase power, refrigerant R22 , please call staff for other parameters
• Specifications and performance are subject to change without prior notice.

AIR-COOLED Chiller
Model HTC5F HTC8F HTC10F HTC12F HTC15F HTC20F HTC25F HTC30F HTC40F HTC50F
Cooling Capacity kw/h 50Hz
60Hz
13
16
21
25
26
31
30
36
42
50
55
66
60
71
84
100
111
133
199
143
Kcal/h 50Hz
60Hz
11223
13488
17630
21156
22446
26935
25585
30702
35948
43138
47558
57070
51170
61404
71896
86258
95116
114139
102512
123015
Input Power kW 6 8 10 12 16 20 23 33 41 48
Voltage 3PH-380V-50Hz (Or 200V/220V/415V 50Hz/60Hz)
Refrigerant Name R22 (Or R134a/R407c)
Control Method Externally balanced thermal expansion valve
Compressor Type Hermetic gyral type
Power(kW) 3.73 5.97 7.46 8.95 11.19 14.92 18.64 22.38 29.84 37.28
Evaporator Type Water tank with coil
Chilled Water
(m³/h)
 
2.24
2.68
3.52
4.22
4.47
5.37
5.12
6.15
7.20
8.63
9.52
11.42
10.25
12.29
14.39
17.37
19.05
29.86
20.50
24.60
Water Tank
(L)
 
50 120 120 120 200 250 250 250 320 370
Water Pipe
(Inch)
 
1 1- 1/ 2 1- 1/ 2 2 2 2 2- 1/ 2 2- 1/ 2 3 3
Condenser Type High efficiency copper tube sleeve aluminum fin type + low noise outer rotor fan
Air Cooling
(m³/h)
5000 8000 10000 12000 15000 20000 25000 30000 40000 50000
Pump Power
(KW)
0.37 0.75 0.75 0.75 1.5 2.25 2.25 2.25 3.75 4.5
Head, H (m) 20 22 22 22 24 30 30 30 40 52
Dimension L (MM) 1390 1600 1600 1370 1875 2265 2335 1920 1920 2090
W (MM) 640 860 860 940 1100 1100 930 1650 1650 2020
H (MM) 1095 1555 1555 1750 1750 1700 1700 2100 2100 2100
Weight Kg 300 400 450 450 600 880 980 1100 1250 1400
Unit Conversion 1KW=860KCAL/HR 1RT=3024KCAL/HR 1BTU/HR=0.252KCAL/HR
Note: 
Working condition: Chilled water temperature range: 3°C to 35°C, temperature difference between inlet and outlet chilled water: 3°C to 8°C, cooling water temperature range: 18°C to 37°C,  temperature difference between inlet and outlet cooling water: 3.5°C to 10°C
Nominal cooling capacity calculated according to: inlet/outlet chilled fluid temperature: 12°C/7°C, inlet/outlet cooling water temperature: 30°C/35°C
• The above parameters are test results based on voltage 380V 50HZ 3-phase power, refrigerant R22 , please call staff for other parameters
• Specifications and performance are subject to change without prior notice.


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
12
Year of Establishment
2016-03-15